Ultrasonic Bolt Measure Devices
Home:
Products:
Bolting Accessory Tooling:
Ultrasonic Bolt Measure Devices
|
State-of-the-art ultrasonic bolt measurement allows you to know exactly what bolt load is retained.
Key Features:
- Portable, handheld units.
- Battery operated.
- High resolution display.
- Temperature compensation.
- Interchangeable transducers.
- Windows software.
- Built-in probe zero block allows easy exchange of transducers.
- Regression analysis for custom material calibration.
- Windows software to download measurements create reports, and upload test parameters.
- Direct-to-printer reports.
Model UT1
- Measures bolts up to 250 inches in length.
- Stores 10,000 readings.
Model UT2
- Measures bolts up to 48 inches in length.
- Stores 8,000 readings.
|
| Width |
7.5 in. (191 mm) |
| Height |
5.5 in. (140 mm) |
| Depth |
2.2 in. (56 mm) |
| Weight |
2.5 lbs. (1.14 kg) with batteries. |
| Misc. |
Shock-resistant plastic case, weather-resistant key pad. |
| Graphic Waveform LCD |
1/4 VGA |
| Viewing Area (w x h) |
3.8 x 2.8 in. (96 x 71 mm) |
| Pixel Density (w x h) |
320 x 240 |
| Update Rate |
4 Hz |
| Misc. |
Adjustable contrast and blacklight, four-level ZOOM for signal enlargement. |
| Measurable Fastener Length |
0.75 to 250 in. (19 to 6,350 mm) |
| Fastener and Test Memory |
10,000 fasteners in 512 groups. |
| Measurement Modes |
Initial to first pulse; multiple echo for short fasteners. |
| Units |
Load, stress and neogation in English and Metric units. |
| Stored Material Constants |
12 common fastener materials. |
| Power Supply |
5 “AA” Alkaline or NiCad batteries. Interchargeable and easy-to-access operating time: 40 hours without blacklight A.C. Power (85 to 260 volt). |
| Operating Temperature |
+10 to +120°F (-10 to +50°C) |
| Warranty |
Bolttech warrants that (1) the BoltSpan will perform substantially in accordance with accompanying written materials for a period of two years from the date of receipt; and (2) any hardware accompanying the unit, excluding transducers, batteries, temperature probes, and cables, will be free from defects in materials and workmanship under normal use and service for a period of two years from the date of receipt. Should any problem occur caused by a defect in materials or workmanship within two years after receipt by end user, it will be repaired or replaced at no cost for parts or labor when returned prepaid to Bolttech.
This warranty does not apply in cases of abuse, mishandling, unauthorized use or repair. Bolttech Corporation shall make the final determination regarding the appropriateness of any warranty claim. Any implied warranties on the BoltSpan hardware or software are limited to two years.
All repair work will be made FOB West Newton, Pennsylvania or at a Factory Trained Service Center as advised by Bolttech, provided defective unit is returned properly packed with all transportation charges prepaid. Any and all equipment replacement will be at the sole discretion of Bolttech.
|